日本北阳HOKUYO DC-M系列电子计数器

产品编号:20925-904

产品型号:DC-M系列

市场价格:0元/台

批发价格:0元/台

更新时间:2011.03.29

浏览次数:

详细信息

特点

  • 所有型号提供增/减计数,由于宽电压100 to 240VAC,所以应用广泛。

规格

72×72mm型

类型

增/减型 总数计数器

增/减型 预置计数器

型号

DC-MA6-D

DC-MB6-D

Display

Red LED 7-segment LED(Height10mm, width5.7mm), Range: 999999 to -99999 (Zero-suppress)

Number of digit

6 digits

电源

100 to 240VAC(50/60Hz)

Fluctuation range

-15% to +10%

电力消耗

Approx. 4.5VA(when 240VAC)

计数

Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H”

预设


1

预设方法


Digital switch for each digit

计数速度

30Hz: Min. signal width 16.7msec, make-ratio 1:1
5kHz: Min. signal width 100μsec, make-ratio 1:1(Changeover by slide switch)

Counting prohibited

Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz)

Counting/ reset/counting prohibited input

Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened)

控制输出

 operation

Self-holding operation: It operates when preset value and returns by reset
Single-shot operation: It operates when preset value and returns after specific time(200ms)

传感器供电

12VDC(+10%, -10%), 100mA(Ripple 5% or less)

Ambient temperature, humidity

-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH

Memory time against power failure

Memory time/once: approx. 10 years, memory numbers: 0.1 million times

外壳材料

外壳: ABS树脂, 防尘盖: 聚碳酸酯

附件

防尘盖, 金属安装架

 


72×144mm型

类型

Increment/decrement type total counter

Increment/decrement type preset counter

Increment/decrement type 2-preset counter

型号

DC-MA6-E

DC-MB6-E

DC-MC6-E

显示位数

Red LED 7-segment LED(Height15mm, width8.8mm), Range: 999999 to -99999 (Zero-suppress)

 

6 digits

电源

100 to 240VAC(50/60Hz)

Fluctuation range

-15% to +10%

Power consumption

約4.5VA(when 240VAC)

Counting

Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H”

Preset


2

Preset method


Digital switch for each digit

Counting speed

30Hz: Min. signal width 16.7msec, make-ratio 1:1
5kHz: Min. signal width 100μsec, make-ratio 1:1(Changeover by slide switch)

Counting prohibited

Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz)

Counting/ reset/counting prohibited input

Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened)

Control output operation

Self-holding operation: It operates when preset value and returns by reset
Single-shot operation: It operates when preset value and returns after specific time(200ms)

Power source for sensor

12VDC(+10%, -10%), 100mA(Ripple 5% or less)

Ambient temperature, humidity

-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH

Memory time against power failure

Memory time/once: approx. 10 years, memory numbers: 0.1 million times

Case

Case: ABS resin, dust-proof cover: polycarbonate

Attachment

Dust-proof cover, fitting metal

* DC-MOW with BCD read-out output is also lined up. Ask us in details.

外部尺寸

72×72mm型

 


开孔尺寸

 

72×144mm型

 


开孔尺寸

 

连接

输入/晶体管输出

接点/晶体管集电极开路输入

电压输入 


连接

DC-M_Connection 72×72mm型

接点/集电极开路输入

Note) Count 1 terminal [8] is increment, Count 2 terminal [9] is decrement. In case of 90 phase-difference input, when Count 1 is shifted shifted by 90°, it is increment counting, and when Count 2 is shifted 90°, it is decrement counting.
Note) In case of Total counter, [4] [5] [6] terminal are not used.
Note) FG [3] terminals should be grounded.


DC-M_Connection 2×144mm型

接点/集电极开路输入

Note) Terminals [11] and [18] are connected inside
Note) Count 1 [12] is increment counting and Count 2 [13] is decrement counting. In case of 90°phase-difference input, when Count 1 is shifted by 90°, it is increment counting, and when Count 2 is shited by 90°, it is decrement counting.
Note) In case of total counter, [4] [5] [6] [7] [8] [9] [16] [17] terminals are not used.
Note) In case of preset counter (1 preset type), [4] [5] [6] [16] terminals are not used.
Note) FG ([3] terminal) should be grounded.

 

注意)

* Do not use unused terminal as relay terminal.
* Each input to counting, reset and count prohibition is common use for contact and open-collector. Wire to each input and output terminal 2-core shield wire or metal conduit tube as short as possible. Do not lay the wires close to or parallel to line cable, power cable or high voltage line.
* For connection, use M3 pressure connection terminals.

产品中心&导购    |    关于邦硕    |    代理品牌    |    技术资料&下载    |    联系我们
友情链接:639电子网    福禄克仪表FLUKE    
 日本岛电(SHIMADEM)浙江一级代理
© 杭州邦硕电子有限公司 www.hzd7.com 2010 All Rights Reserved
    地 址: 杭州市余杭区博园路1号杭州电子市场西区3楼3D115,3C060     商务电话: 0571-89901383 89902096     商务传真: 0571-89902096     E-Mail : ks2096@163.com
 后台管理  技术支持:陆山久(639)网络 浙ICP备15014926号-1